© 2014 AEM Performance Electronics
MSD Distributor + ATI AEM 24 Tooth + Honeywell Hall Effect Sensor
1. Modify and install mechanical advance distributor. (See Modifying Mechanical Advance Distributor, in
this document.)
2. Install ATI AEM Infinity crank trigger. (Note that an adjustable sensor mount is not provided with the
ATI crank trigger.) Position the crank sensor to be near the middle of its adjustment range while being
in between crank teeth with the engine at TDC. Set sensor air gap to .020”.
3. Wiring:
Crank Sensor – Honeywell Hall Effect Sensor
Cam Sensor – Modified MSD Distributor
Note: Use shielded twisted pair wiring w/drain to ground.
Note: Use shielded wiring with drain to ground.
4. Load ATI 24 + Honeywell Hall base session and review Setup Wizard. (See Setup Wizard, in this
document.)
5. Sync ignition timing. (See Syncing Ignition Timing, in this document.)